AILV MATERIALS · EXHAUST AIR
An exhaust HEPA box joins the filter housing to the exhaust duct. The drawing should identify the duct flange, filter access and any monitoring or test connections required for the selected assembly.
|
Air tightness of box body |
0.1% chamber volume at + 1000 and-1000Pa |
|
Box resistance to pressure |
≥2500Pa |
|
filter efficiency |
≥99.995%@MPPS |
|
Filter pickup mode |
In-situ manual / automatic scanning for leak collection; |
|
Deal with air volume |
240m³ / h-2000m³ / h (according to different models); |
|
Resistance detection method |
Real-time monitoring of mechanical type differential pressure meter or variable type differential pressure sensor |
|
Disinfection method of the filter |
Can be sterilized in situ |
|
resistance to corrosion |
Made of high quality stainless steel, inside and outside full welding disinfectant, detergent and acid, alkali |
|
High efficiency particulate air filter |
Air volume (0.9 m/s) |
Box size |
The wind flange |
|
|
circular |
rectangle |
|||
|
HxWxD |
CHM |
HxWxD |
ΦD |
AxB |
|
305X305X93 |
300 |
735X465X450(+60) |
150 |
200X150 |
|
610X305X93 |
600 |
735X770X450(+60) |
200 |
200X200 |
|
610X530X93 |
1000 |
1040X690X450(+60) |
250 |
320X200 |
|
610X610X93 |
1250 |
1040X770X450(+60) |
300 |
320X250 |
|
610X762X93 |
1500 |
1040x922X450(+60) |
300 |
320X320 |
|
610X762X117 |
2000 |
1040X922X470(+60) |
350 |
400X320 |
● Box body material: 2.0mm304 stainless steel;
● Including: disinfection mouth, PAO injection and detection port, automatic / manual scanning system, filter resistance monitoring system
● Air volume: 240m'/ h-2000m / h (according to different models)
● Filter: High-efficiency filter
● Seal method: dry gasket seal.
Note:
(1) Installation and opening dimension W1 + 10) (D1 + 10)
(2) The "+ 60" is the height of the inlet air flange
Place the filter access door and maintenance area on the duct layout. Avoid arranging adjacent equipment where it obstructs inspection or the planned filter removal route.
Identify the flange form and any required test, scanning or monitoring points. Tie those items to the selected housing reference rather than treating them as a generic package.
Describe the exhaust process and the documents your team needs for acceptance. Keep these requirements with the housing and filter schedule when comparing the proposed assembly.
▤ Include the selected exhaust housing and filter references, duct connection, access-door orientation and quantities. List any required monitoring or test connections in the proposed supply package.