Cleanroom HEPA Exhaust Box

short description:

AILV exhaust HEPA box selection connects the housing and filter to your exhaust duct, service route and specified monitoring or test points.


Product Specification

Order Scope

Product Tags

Factory Show

Filter housing with a perforated grille and upper access panel
Filter housing with a perforated grille and upper access panel.

AILV MATERIALS · EXHAUST AIR

Make the exhaust-side service route clear

An exhaust HEPA box joins the filter housing to the exhaust duct. The drawing should identify the duct flange, filter access and any monitoring or test connections required for the selected assembly.

Published Unit Details

Air tightness of box body

0.1% chamber volume at + 1000 and-1000Pa

Box resistance to pressure

≥2500Pa

filter efficiency

≥99.995%@MPPS

Filter pickup mode

In-situ manual / automatic scanning for leak collection;

Deal with air volume

240m³ / h-2000m³ / h (according to different models);

Resistance detection method

Real-time monitoring of mechanical type differential pressure meter or variable type differential pressure sensor

Disinfection method of the filter

Can be sterilized in situ

resistance to corrosion

Made of high quality stainless steel, inside and outside full welding disinfectant, detergent and acid, alkali

Dimensions & Connections

High efficiency particulate air filter

Air volume (0.9 m/s)

Box size

The wind flange

circular

rectangle

HxWxD

CHM

HxWxD

ΦD

AxB

305X305X93

300

735X465X450(+60)

150

200X150

610X305X93

600

735X770X450(+60)

200

200X200

610X530X93

1000

1040X690X450(+60)

250

320X200

610X610X93

1250

1040X770X450(+60)

300

320X250

610X762X93

1500

1040x922X450(+60)

300

320X320

610X762X117

2000

1040X922X470(+60)

350

400X320

● Box body material: 2.0mm304 stainless steel;

● Including: disinfection mouth, PAO injection and detection port, automatic / manual scanning system, filter resistance monitoring system

● Air volume: 240m'/ h-2000m / h (according to different models)

●  Filter: High-efficiency filter

● Seal method: dry gasket seal.

 

Note:

(1) Installation and opening dimension W1 + 10) (D1 + 10)

(2) The "+ 60" is the height of the inlet air flange

Order Preparation

Locate the service side

Place the filter access door and maintenance area on the duct layout. Avoid arranging adjacent equipment where it obstructs inspection or the planned filter removal route.

List the specified connections

Identify the flange form and any required test, scanning or monitoring points. Tie those items to the selected housing reference rather than treating them as a generic package.

Define the exhaust application

Describe the exhaust process and the documents your team needs for acceptance. Keep these requirements with the housing and filter schedule when comparing the proposed assembly.


  • Previous:
  • Next:

  • ▤ Include the selected exhaust housing and filter references, duct connection, access-door orientation and quantities. List any required monitoring or test connections in the proposed supply package.